There is a programming error in the calculations of "line purity". The error affects any targets with more than one line; the more lines the worse the error. The plots and tables for "line purity" from the online catalog should not be used until corrections have been made.
Set 1: K-edge group, unfiltered. Target Voltages (kV): 16.663 24.995 33.326 41.658 PEIS Source Model: table plot1 plot2 At Focal Plane: table plot1 plot2 ACIS, Backside-Illuminated: table plot1 plot2 ACIS, Frontside-Illuminated: table plot1 plot2 HRC, CsI MCP + UV shield: table plot1 plot2
Set 2: K-edge group, Ni filter. Target Voltages (kV): 16.663 24.995 33.326 41.658 Filter Thickness (micron): 0 19.5 39. 78. 117. 156. 195. PEIS Source Model (filtered): table plot At Focal Plane: table plot line purity - table plot (Ka2) plot (Ka1) plot (Kb) ACIS, Backside-Illuminated: table plot line purity - table plot (Ka2) plot (Ka1) plot (Kb) ACIS, Frontside-Illuminated: table plot line purity - table plot (Ka2) plot (Ka1) plot (Kb) HRC, CsI MCP + UV shield: table plot line purity - table plot (Ka2) plot (Ka1) plot (Kb)
Set 3: K-edge group, Co filter. Target Voltages (kV): 16.663 24.995 33.326 41.658 Filter Thickness (micron): 0 23.2 46.3 92.6 139. 185. 232. PEIS Source Model (filtered): table plot At Focal Plane: table plot line purity - table plot (Ka2) plot (Ka1) plot (Kb) ACIS, Backside-Illuminated: table plot line purity - table plot (Ka2) plot (Ka1) plot (Kb) ACIS, Frontside-Illuminated: table plot line purity - table plot (Ka2) plot (Ka1) plot (Kb) HRC, CsI MCP + UV shield: table plot line purity - table plot (Ka2) plot (Ka1) plot (Kb)
Set 4: L-edge group, unfiltered. Target Voltages (kV): 1.707 2.561 3.414 4.268 PEIS Source Model: table plot1 plot2 At Focal Plane: table plot1 plot2 ACIS, Backside-Illuminated: table plot1 plot2 ACIS, Frontside-Illuminated: table plot1 plot2 HRC, CsI MCP + UV shield: table plot1 plot2
Set 5: L-edge group, Ni filter. Target Voltages (kV): 1.707 2.561 3.414 4.268 Filter Thickness (micron): 0 0.624 1.25 2.5 3.75 5. 6.25 PEIS Source Model (filtered): table plot At Focal Plane: table plot line purity - table plot (Ll) plot (Leta) plot (La) plot (Lb) ACIS, Backside-Illuminated: table plot line purity - table plot (Ll) plot (Leta) plot (La) plot (Lb) ACIS, Frontside-Illuminated: table plot line purity - table plot (Ll) plot (Leta) plot (La) plot (Lb) HRC, CsI MCP + UV shield: table plot line purity - table plot (Ll) plot (Leta) plot (La) plot (Lb)
Editor: Dr. Douglas Swartz System Administrator: Mr. Bob Dean Privacy Policy and Important Notices Accessibility Statement |